Background: the optimal period over which respiratory rate should be measured is uncertain.
Setting: medical ward of low resource Ugandan hospital,
Methods: comparison of the first respiratory rates measured on admission over seconds using a smartphone application with measurements over 15 minutes using a piezoelectric device.
Results: There was a poor correlation between respiratory rates measured by the piezoelectric device and rates measured by a smartphone application. Although the discrimination for mortality of piezoelectric respiratory rates were slightly higher than those derived from the application, there were not statistically significant differences.
Conclusion: this study could not demonstrate potential clinical benefits that justify measuring the first respiratory rate after admission over 15 minutes by a device.
Should respiratory rate be measured on admission over a few seconds by a smartphone application or over 15 minutes by a piezoelectric device? A prospective observational pilot study of acutely ill medical patients admitted to alow-resource Ugandan hospital
6th November 2024
PMID: 39513260
| Authors | Affiliations |
|---|---|
| Franck Katembo Sikakulya | Faculty of Clinical Medicine and Dentistry, Department of Surgery, Kampala International University Western Campus, Ishaka-Bushenyi, Uganda Faculty of Medicine, Université Catholique du Graben, Butembo, Democratic Republic of the Congo |
| Immaculate Nakitende | Nurse, Emergency and out-patient department, Kitovu Hospital, Masaka, Uganda |
| Joan Nabiryo | Nurse, Emergency and out-patient department, Kitovu Hospital, Masaka, Uganda |
| Sylivia Namuleme | Director of Nursing, Kitovu Hospital, Masaka, Uganda |
| Alfred Lumala | Medical Director, Kitouv Hospital, Masaka, Uganda |
| John Kellett | Visiting Professor, School of Clinical and Biomedical Sciences, University of Bolton, United Kingdom |
Should respiratory rate be measured on admission over a few seconds by a smartphone application or over 15 minutes by a piezoelectric device? A prospective observational pilot study of acutely ill medical patients admitted to alow-resource Ugandan hospital
Cite this article as:
Sikakulya FK, Nakitende I, Nabiryo J, Namuleme S, Lumala A, Kellett J. Should respiratory rate be measured on admission over a few seconds by a smartphone application or over 15 minutes by a piezoelectric device? A prospective observational pilot study of acutely ill medical patients admitted to a low-resource Ugandan hospital. Acute Med. 2024;23(3):118-126. doi: 10.52964/AMJA.0986. PMID: 39513260.
