Point of care ultrasound scanning (POCUS) is safe and effective in positively identifying lower limb DVT in emergency departments globally. In the UK, the requisite knowledge and skills are integrated into the FAMUS and FUSIC curricula.
Five FAMUS practitioners of varying experience performed 3-point compression POCUS on medical ambulatory and inpatients. Accuracy and timing of POCUS was compared between practitioners and with subsequent departmental scans.
89% sensitivity and 97% specificity were observed, with little difference between supervisors and candidates. Additionally, a significantly higher proportion of POCUS vs departmental scans (69% vs 7%, p = 0.0001) occurred within 24 hours of request.
Minimal experience was required to produce accurate results within ambulatory and internal medicine settings, and significant time savings can be made.
References
- Dehbozorgi A, Damghani F, Mousavi-Roknabadi R, et al. Accuracy of three-point compression ultrasound for the diagnosis of proximal deep-vein thrombosis in emergency department. Journal of Research in Medical Sciences. 2019;24(1):80-.
- Lee JH, Lee SH, Yun SJ. Comparison of 2-point and 3-point point-of-care ultrasound techniques for deep vein thrombosis at the emergency department A meta-analysis. MEDICINE.2019;98(22):e15791.
- Situ-LaCasse E, Guirguis H, Friedman L, et al. Can emergency physicians perform extended compression ultrasound for the diagnosis of lower extremity deep vein thrombosis? WORLD JOURNAL OF EMERGENCY MEDICINE. 2019;10(4):205-9.
- Smallwood N, Dachsel M, Matsa R, et al. Focused Acute Medicine Ultrasound (FAMUS) - Point of care ultrasound for the Acute Medical Unit. Acute Medicine. 2016;15:193.
- ICS. FUSIC_accreditation 2020 [Available from: https://www.ics.ac.uk/ICS/FUSIC/FUSIC_Accreditation/ICS/FUSIC/FUSIC_Accreditation.aspx?hkey=03ef026c-cd0c-4bba-9555-8c85bb220b01.]
- NICE. National Institute for Clinical Excellence. Venous thromboembolic disease: diagnosis, management and thrombophilia testing. [Internet] London: NICE 2020 [updated 26/03/2020;cited 2020 06/29/2020]. Available from: https://www.nice.org.uk/guidance/ng158.
- Goodacre S, Sampson F, Thomas S, et al. Systematic review and meta-analysis of the diagnostic accuracy of ultrasonography for deep vein thrombosis. BMC Medical Imaging. 2005;5(1):6.