Point-of-care lung ultrasound in the assessment of suspected COVID-19: a retrospective service evaluation with a severity score

Point-of-care lung ultrasound in the assessment of suspected COVID-19: a retrospective service evaluation with a severity score

Introduction: Point-of-care lung ultrasound (POCUS) has been advocated as a tool to assess the severity of COVID19 and thereby aid risk stratification.

Methods: We conducted a retrospective service evaluation between the 3rd March and the 5th May 2020 to describe and characterise the use of POCUS within an acute care pathway designed specifically for the assessment of suspected or confirmed COVID-19. A novel POCUS severity scale was formulated by assessing pleural and interstitial abnormalities within six anatomical zones (three for each lung). An aggregated score was calculated for each patient and evaluated as a marker of disease severity using standard metrics of discriminatory performance.

Results: POCUS was performed in the assessment of 100 patients presenting with suspected COVID-19. POCUS was consistent with COVID-19 infection in 92% (n = 92) of the patients assessed. Severity, as assessed by POCUS, showed good discriminatory performance to predict all-cause inpatient mortality, death or critical care admission, and escalated oxygen requirements (AUC .80, .80, 82). The risk of all-cause mortality in patients with scores in lowest quartile was 2.5% (95%CI 0.12- 12.95) compared with 42.9% (95CI 15.8 – 75.0%) in the highest quartile. POCUS assessed severity correlated with length of stay and duration of supplemental oxygen therapy.

Conclusion: A simple aggregated score formed by the summating the degree of pleural and interstitial change within six anatomical lung zones showed good discriminatory performance in predicting a range of adverse outcomes in patients with suspected COVID-19.

References

  1. Zhu N, Zhang D, Wang W, et al. A novel coronavirus from patients with pneumonia in China, 2019. N Engl J Med 2020; 382: 727–73.
  2. Guan WJ, Zhong NS. Clinical Characteristics of Covid-19 in China. Reply. N Engl J Med. 2020; 382(19): 1861–1862. doi:10.1056/NEJMc2005203.
  3. A Wang Y, Liu Y, Liu L. Clinical Outcomes in 55 Patients With Severe Acute Respiratory Syndrome Coronavirus 2 Who Were Asymptomatic at Hospital Admission in Shenzhen, China. J Infect Dis. 2020; 221(11): 1770
  4. Docherty, B. Features of 16,749 hospitalised UK patients with COVID-19 using the ISARIC WHO Clinical Characterisation Protocol.
  5. Safiya Richardson, Jamie S. Hirsch, Mangala Narasimhan, et al. Presenting Characteristics, Comorbidities, and Outcomes Among 5700 Patients Hospitalized With COVID-19 in the New York City Area JAMA. 2020; doi:10.1001/jama.2020.6775.
  6. Fei Zhou, Ting Yu, Ronghui Du. Clinical course and risk factors for mortality of adult inpatients with COVID-19 in Wuhan, China: a retrospective cohort study. Lancet 2020;395: 1054–62.
  7. Zanobetti M, Scorpiniti M, Gigli C, et al. Point-of-Care Ultrasonography for Evaluation of Acute Dyspnea in the ED. Chest. 2017; 151(6): 1295–1301. doi:10.1016/j.chest.2017.02.003.
  8. Lichtenstein D. Goldstein I. Mourgeon E, et al. Comparative diagnostic performances of auscultation, chest radiography, and lung ultrasonography in acute respiratory distress syndrome. Anesthesiology 2004; 100: 9–15.
  9. Diagnostic Accuracy of Point-of-Care Lung Ultrasonography and Chest Radiography in Adults With Symptoms Suggestive of Acute Decompensated Heart Failure A Systematic Review and Metaanalysis JAMA Netw Open. 2019; 2(3): e190703. doi:10.1001/jamanetworkopen.2019.0703.
  10. Alber KF, Dachsel M, Gilmore A, et al. Focused Acute Medicine Ultrasound (FAMUS). Acute Med. 2018; 17(3): 164–167.
  11. Intensive Care Society, Core Ultrasound in Intensive Care (CUSIC) https://www.ics.ac.uk/ICS/cusic.aspx.
  12. Danilo Buonsenso Davide Pata Antonio Chiaretti COVID-19 outbreak: less stethoscope, more ultrasound. The Lancet Respiratory Medicine: 2020; 8(5).
  13. Peng Q, Wang X, Zhang L. Findings of lung ultrasonography of novel corona virus pneumonia during the 2019–2020 epidemic. Intensive Care Med. (2020). https://doi.org/10.1007/s00134-020-05996-6.
  14. Buonsenso D, Piano A, Raffaelli F, et al. Point-of-Care Lung Ultrasound findings in novel coronavirus disease-19 pnemoniae: a case report and potential applications during COVID-19 outbreak. Eur Rev Med Pharmacol Sci. 2020; 24(5): 2776–80.
  15. Yasukawa K, Minami T. Point-of-Care Lung Ultrasound Findings in Patients with Novel Coronavirus Disease (COVID-19) Pneumonia [published online ahead of print, 2020 Apr 24]. Am J Trop Med Hyg. 2020;10.4269/ajtmh.20-0280. doi:10.4269/ajtmh.20-0280.
  16. Smith MJ, Hayward SA, Innes SM, et al. Point-of-care lung ultrasound in patients with COVID-19 - a narrative review [published online ahead of print, 2020 Apr 10]. Anaesthesia. 2020;10.1111/anae.15082. doi:10.1111/anae.15082.
  17. Gargani, L Soliman-Aboumarie, H Volpicelli, G. Why, when, and how to use lung ultrasound during the COVID-19 pandemic: enthusiasm and caution, European Heart Journal - Cardiovascular Imaging jeaa163, https://doi.org/10.1093/ehjci/jeaa163.
  18. Office of National Statistics: Deaths involving COVID-19 by local area and socioeconomic deprivation: deaths occurring between 1 March and 30 June 2020. accessed: https://www.ons.gov.uk/peoplepopulationandcommunity/birthsdeathsandmarriages/deaths/bulletins/deathsinvolvingcovid19bylocalareasanddeprivation/
    deathsoccurringbetween1marchand30june2020
  19. Volpicelli G, Lamorte A, Villén T. What’s new in lung ultrasound during the COVID-19 pandemic [published online ahead of print, 2020 May 4]. Intensive Care Med. 2020; 1–4. doi:10.1007/s00134-020-06048-9.
  20. Lichtenstein DA, Meziere GA. Relevance of lung ultrasound in the diagnosis of acute respiratory failure: the BLUE protocol. Chest. 2008; 134(1): 117-25.
  21. Clegg A, Bates C, Young John. Development and Validation of an Electronic Frailty Index Using Routine Primary Care Electronic Health Record Data Age Ageing (2016) May; 45(3): 353–60. doi:10.1093/ageing/afw039. Epub 2016 Mar 3.
  22. Public Health England. COVID-19: review of disparities in risks and outcomes (2020) https://www.gov.uk/government/publications/covid-19-review-of-disparities-in-risks-and-outcomes.
  23. Soldati G, Smargiassi A, Inchingolo R, et al. Proposal for International Standardization of the Use of Lung Ultrasound for Patients With COVID-19: A Simple, Quantitative, Reproducible Method [published online ahead of print, 2020 Mar 30]. J Ultrasound Med. 2020;10.1002/jum.15285. doi:10.1002/jum.15285.

Request Permissions

To request copyright permission to republish or share portions of our works, please visit Copyright Clearance Center’s (CCC) Marketplace website by clicking the button below:

Get Permission

Point-of-care lung ultrasound in the assessment of suspected COVID-19: a retrospective service evaluation with a severity score

16th November 2020
PMID: 33215172
Authors Affiliations
Thomas Knight Sandwell and West Birmingham NHS Trust, Department of Acute Medicine, Birmingham, United Kingdom
Lloyd Edwards Sandwell and West Birmingham NHS Trust, Department of Acute Medicine, Birmingham, United Kingdom
Arvind Rajasekaran Sandwell and West Birmingham NHS Trust, Department of Acute Medicine, Birmingham, United Kingdom
Sarbjit Clare Sandwell and West Birmingham NHS Trust, Department of Acute Medicine, Birmingham, United Kingdom
Daniel Lasserson Sandwell and West Birmingham NHS Trust, Department of Acute Medicine, Birmingham, United Kingdom

Point-of-care lung ultrasound in the assessment of suspected COVID-19: a retrospective service evaluation with a severity score

Cite this article as:

Knight T, Edwards L, Rajasekaran A, Clare S, Lasserson D. Point-of-care lung ultrasound in the assessment of suspected COVID-19: a retrospective service evaluation with a severity score. Acute Med. 2020;19(4):192-200. PMID: 33215172.

Point-of-care lung ultrasound in the assessment of suspected COVID-19: a retrospective service evaluation with a severity score

Share this article

Click the icon of the social media platform on which you would like to share this article.


Shopping Basket